MGS – Murco Gas Sensor EC / SC model
Gas Detector and Transmitter
Installation & Operation*
Content Page
1- Installation Instructions 2
2- Location Instructions 2
3- Typical Settings 2
4- Installation and Wiring Diagrams 2
5- Operating Instructions 2
6- Test/Function Instructions 3
7- Remote sensor head installation 3
8- MGS - Annual test 3
9- Agree Selectable functions with end-users 4
10- Troubleshooting 4
11- Connections to Murco Control Panels 4
12- Mounting Diagrams 4
08 ASH (1)
*Technician use only
This unit must be installed by a suitably qualified technican who will install this unit in accordance with these instructions and the
standards set down in their particular industry/country. Suitably qualified operators of the unit should be aware of the regulations and
standards set down by their industry/country for the operation of this unit. These notes are only intended as a guide and the
manufacturer bears no responsibility for the installation or operation of this unit.
Failure to install and operate the unit in accordance with these instructions and with industry guidelines may cause serious injury
including death and the manufacturer will not be held responsible in this regard.
Murco Ltd.
114a Georges Street Lower, Dun Laoghaire Co Dublin. Ireland,
e-mail: info@murco.ie web: www.murco.ie
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - Installation & Operation*

1MGS – Murco Gas Sensor EC / SC modelGas Detector and TransmitterInstallation & Operation*Content Page1- Installation Instructions 22- Location In

Page 2

21- MGS Installation InstructionsTo open the Standard Sensor enclosure: turn the cable gland ½ turnanticlockwise to loosen the internal gland nut, dep

Page 3 - Semiconductor Sensor

3For further detailed Installation tips covering most installations and equipmenttypes.. chillers, air cooled chillers etc see our web site www.murco.

Page 4 - 2 x Clearance for M6

4Agree Selectable functions with end-users:You should agree these important functions with the customer so thatthe system will operate as he/she requi

Page 5

514770114160180O3/4'' UNI ISO 7/1 RCO3/4'' UNI ISO 7/1 RCO8ExdIP66Remote Exd Sensor Head 5m Cable Vent Pipe Outdoor 1’’ BSP Head 3

Page 6 - Relay Expander Box

64,6 Sensor Controller EnclosureRelay Expander Box1,2 Sensor Controller Enclosure15.515.015.012.774.512.715.59.09.04.8 5.050.010.035.0 25.015.515.02